Thursday, March 31, 2016

HOW-TO: Brocade Network configuration

Original text from link: https://alteeve.ca/w/Configuring_Brocade_Switches

Validated Switches

The following switches (and firmwares) have been validates to work with the Anvil!:
  • ICX6610
    • 7.40d
  • ICX6450
    • 7.40a
    • 7.40e
    • 8.00a

Serial Connection

Template note icon.png
Note: Depending on your terminal emulator, the key may not work. If it doesn't, try pressing ctrl + h to delete the character to the left of your cursor.
You can use screen to connect to the switch (default values are fine). The example below is what you would use on most servers with an on-board serial port. If you have two, then port two would be /dev/ttyS1. If you are using a USB to serial adapter, then you will use /dev/ttyUSB0 (or if it is a multi-port adapter, /dev/ttyUSB1, etc). If none of these work, you will need to consult your operating system documentation and/or serial port adapter to determine the proper /dev/ttyX device to use.
screen /dev/ttySO
The screen will be blank until you press .
ICX6610-48 Switch>
To log in;
ICX6610-48 Switch>enable 
No password has been assigned yet...
There is no default user name and password.

Exiting screen

To end your screen session, press ctrl + a together, release and then press k.
You will be asked if you want to kill the session, press y to confirm.
Really kill this window [y/n]
[screen is terminating]

Configure a Password

To use the web interface later, a user and password needs to be set.
Template note icon.png
Note: Super User level password can be an alphanumeric string, but cannot begin with a number.
ICX6610-48 Switch#configure terminal
ICX6610-48 Switch(config)#enable super-user-password secret
ICX6610-48 Switch(config)#enable user disable-on-login-failure 10
ICX6610-48 Switch(config)#user alteeve privilege 0 password secret
ICX6610-48 Switch(config)#show users
Username                                        Password                           Encrypt   Priv Status   Expire Time
======================================================================================================================
alteeve                                         $1$HF4..Zv.$uF.PUT.bqkMy5GicUIrhG/ enabled   0    enabled  Never
To enable the web interface;
ICX6610-48 Switch(config)#aaa authentication web-server default local
ICX6610-48 Switch(config)#write memory
Write startup-config done.
 
Automatic copy to member units:  2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.

Form the Stack

ICX6450 and ICX6610

ICX6610-48 Switch>enable
ICX6610-48 Switch#configure terminal
ICX6610-48 Switch(config)#stack enable
Enable stacking. This unit actively participates in stacking
stacking is enable. optical monitoring for stacking ports 1/2/1, 1/2/6 is not available.
ICX6610-48 Switch(config)#exit
ICX6610-48 Switch#stack secure-setup
Discovering the stack topology...
 
Current Discovered Topology - RING
 
Available UPSTREAM units
Hop(s)  Id      Type          Mac Address
1       new  ICX6610-48     xxxx.xxxx.xxxx
 
Available DOWNSTREAM units
Hop(s)  Id      Type          Mac Address
1       new  ICX6610-48     xxxx.xxxx.xxxx
Do you accept the topology (RING) (y/n)?: y
Selected Topology:
Active  Id      Type          Mac Address
        1    ICX6610-48     yyyy.yyyy.yyyy
 
Selected UPSTREAM units
Hop(s)  Id      Type        Mac Address
1       2    ICX6610-48     xxxx.xxxx.xxxx
 
Selected DOWNSTREAM units
Hop(s)  Id      Type        Mac Address
1       2    ICX6610-48     xxxx.xxxx.xxxx
Do you accept the unit id's (y/n)?: y
T=1d20h24m2.8: Election, was alone --> active, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1, 
T=1d20h24m3.5: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1, 
reset unit 2: u2 diff bootup id=1
Unit 1 loses all neighbors.
Active unit 1 deletes u2 and its config because it is learned.
 
Config changed due to add/del units. Do write mem if you want to keep it
(switch reboots)
T=1d20h26m43.2: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1, 
Done hot swap: active controller unit 1 sets unit 2 to Ready.
 
Config changed due to add/del units. Do write mem if you want to keep it
ICX6610-48 Switch#write memory
Write startup-config done.
 
Automatic copy to member units:  2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
A moment later, more boot messages.
Stack unit 2 Power supply 1 is up
Stack unit 2 Power supply 2 is up
Assigned unit 2 to be standby
start running config sync
Running config sync to standby is complete
ICX6610-48 Switch#show stack
alone: standalone, D: dynamic config, S: static config
ID   Type         Role    Mac Address    Pri State   Comment                   
1  S ICX6610-48   active  xxxx.xxxx.xxxx 128 local   Ready
2  S ICX6610-48   standby yyyy.yyyy.yyyy   0 remote  Ready
 
    active       standby                                                       
     +---+        +---+                                                        
 =2/1| 1 |2/6==2/1| 2 |2/6=                                                    
 |   +---+        +---+   |                                                    
 |                        |                                                    
 |------------------------|                                                    
 
Standby u2 - No hitless failover. Reason: hitless-failover not configured
Current stack management MAC is xxxx.xxxx.xxxx
Note: no "stack mac" config. My MAC will change after failover.
Configure the stack to handle switch "hitless" failure and recovery.
ICX6610-48 Switch#config terminal
ICX6610-48 Switch(config)#hitless-failover enable
Assign a static MAC to the stack. In this case, I always copy stack unit 1's real MAC address.
ICX6610-48 Switch(config)#stack mac cc4e.24b9.5624
Last, switch to unit 2 and change it's priority to match the priority of unit 1.
ICX6610-48 Switch(config)#stack unit 2
ICX6610-48 Switch(config-unit-2)#priority 128
Priority change needs 120 seconds to take effect.
ICX6610-48 Switch(config-unit-2)#exit
ICX6610-48 Switch(config)#write memory
Write startup-config done.
 
Automatic copy to member units:  2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
Two minutes after you change the stack priority, the switch run an election.
Will do election in 30 sec due to priority change
Will do election in 10 sec due to priority change
T=1d20h35m20.2: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1,
Verify the stack is configured the way we want.
ICX6610-48 Switch(config)#show stack
alone: standalone, D: dynamic config, S: static config
ID   Type         Role    Mac Address    Pri State   Comment                   
1  S ICX6610-48   active  xxxx.xxxx.xxxx 128 local   Ready
2  S ICX6610-48   standby yyyy.yyyy.yyyy 128 remote  Ready
 
    active       standby                                                       
     +---+        +---+                                                        
 =2/1| 1 |2/6==2/1| 2 |2/6=                                                    
 |   +---+        +---+   |                                                    
 |                        |                                                    
 |------------------------|                                                    
 
Standby u2 - protocols ready, can failover or manually switch over
Current stack management MAC is xxxx.xxxx.xxxx
Excellent, done.

ICX6430-C12

The ICX6430-C12 doesn't support stacking. However, a stack can be somewhat simulated by tagging a dedicated port with all our VLANs. This will allow traffic from any VLAN to use the same "uplink" port. Also, without a proper stack, we can not create a trunk/LAG. So we enable rapid STP on each switch's customer-facing uplink port instead.

Enable Jumbo Frames

The ICX6610 support packets up to 10240 bytes. That is to say, if jumbo frames are enabled, the MTU of the switch is 10 KiB.
ICX6610-48 Switch#configure terminal
ICX6610-48 Switch(config)#jumbo
Jumbo mode setting requires a reload to take effect!
ICX6610-48 Switch(config)#write memory
Write startup-config done.
 
Automatic copy to member units:  2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
ICX6610-48 Switch(config)#exit
ICX6610-48 Switch#reload
Are you sure? (enter 'y' or 'n'): y
Reload request sent to attached stack member(s)...
 
Rebooting(0)...

Assign IP to Switch

ICX6610-48 Switch#configure terminal
ICX6610-48 Switch(config)#ip address 10.20.1.5 255.255.0.0
ICX6610-48 Switch(config)#exit
The router is at 10.20.255.254, so ping that to verify the IP is configured.
ICX6610-48 Switch#ping 10.20.255.254
Sending 1, 16-byte ICMP Echo to 10.20.255.254, timeout 5000 msec, TTL 64
Type Control-c to abort
Reply from 10.20.255.254   : bytes=16 time<1ms 100="" avg="" is="" max="0/0/0" min="" ms.="" percent="" pre="" rate="" round-trip="" success="" ttl="64">
Good, save the changes.
ICX6610-48 Switch#write memory
Write startup-config done.
 
Automatic copy to member units:  2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.

Update the firmware

Template warning icon.png
Warning: Be sure to have your switches on UPSes before flashing them! As with all devices, a power loss during the flash process may cause the switch to become unusable.

Selecting the Firmware Version

Before we start, we need to decide what version of the firmware we want to install. To do this, start by logging in to your switch(es) and check their current firmware version.
ICX6610-48 Switch#show flash
Stack unit 1:
  Compressed Pri Code size = 5370497, Version:07.3.00fT7f1 (/foundry/FGS/os/FCXS07300f.bin)
  Compressed Sec Code size = 6905002, Version:07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
  Compressed Boot-Monitor Image size = 370555, Version:07.3.02T7f5
  Code Flash Free Space = 52822016
Stack unit 2:
  Compressed Pri Code size = 5370497, Version 07.3.00fT7f1 (/foundry/FGS/os/FCXS07300f.bin)
  Compressed Sec Code size = 6905002, Version 07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
  Compressed Boot-Monitor Image size = 370555, Version 07.3.02T7f5
  Code Flash Free Space = 52822016
Note that both switches are running the major version 07.3.00f. Being that we're interested in High Availability, we are going to be conservative and upgrade to the latest subversion available. Both switches are 7.3, so that is what we will use. If one had been 7.4, for example, then we would have upgraded both to the latest 7.4 version.

Layer 2 vs Layer 3

These switches have two firmwares;
  • Layer 2 (S); This is seen in the above output in the current version's flash file "/foundry/FGS/os/FCXS07300f.bin".
  • Layer 3 (R); This is seen in the above output in the current version's flash file "/foundry/FGS/os/FCXR07300f.bin".
We're only going to update the layer 2 "S" firmware. We don't use the layer 3 features for HA so we won't update them. If you want to updated them, that is fine. The upgrade process below is easily ported to the layer 3 firmware update process.

Downloading the Firmware

To get the firmware:
  • Create or log into your My Brocade account.
  • Click on 'Downloads'.
  • In the Download by select box, select Ethernet Switches.
  • Scroll down and click to expand the arrow to the left of "ICX6610" (or your switch model).
  • Click to expand the version of firmware you want to use. For this tutorial, we're going to be conservative and stay in the same "7.3" release, so we will expand 07300.
  • Click to expand the most recent subversion for your selected firmware major number. In my case, that is "07300j".
  • This takes you to a note about export restrictions. Ensure you meet the criteria and then click to acknowledge compliance, the click on "Submit".
  • You will see the EULA. Read it, understand it and then agree to it by clicking on "I Accept".
  • Save the file on your computer.

Extracting the Image

Navigate to the downloaded file. It will be a .zip file. Expand it. This will create several directories.
To upload the firmware, we need to copy the image to the root of our TFTP server (/var/lib/tftpboot/ on EL6).
Browse into the extracted 07300j/ICX/Images/ directory (or the matching directory for your firmware). You will see two file:
cd 07300j/ICX/Images/
ls -lah
total 12M
drwxr-xr-x 2 root root 4.0K May  8  2014 .
drwxr-xr-x 8 root root 4.0K May  9  2014 ..
-rwxr-xr-x 1 root root 6.7M May  8  2014 FCXR07300j.bin
-rwxr-xr-x 1 root root 5.2M May  8  2014 FCXS07300j.bin
As discussed above, we will be upgrading the layer 2 "S" image. So this is the file we will copy to the TFTP root directory.
cp FCXS07300j.bin /var/lib/tftpboot/
ls -lah /var/lib/tftpboot/FCXS07300j.bin

Performing the Flash

Template note icon.png
Note: We will be flashing both switches at once as they are stacked.
We're ready to flash! So it's time to log into the switch.
ICX6610-48 Switch#copy tftp flash 10.20.255.254 FCXS07300j.bin primary
Flash Memory Write (8192 bytes per dot) 
Automatic copy to member units:  2
........
TFTP to Flash Done.
ICX6610-48 Switch#show flash
Stack unit 1:
  Compressed Pri Code size = 5430491, Version:07.3.00jT7f1 (FCXS07300j.bin)
  Compressed Sec Code size = 6905002, Version:07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
  Compressed Boot-Monitor Image size = 370555, Version:07.3.02T7f5
  Code Flash Free Space = 52690944
Stack unit 2:
  Compressed Pri Code size = 5430491, Version 07.3.00jT7f1 (FCXS07300j.bin)
  Compressed Sec Code size = 6905002, Version 07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
  Compressed Boot-Monitor Image size = 370555, Version 07.3.02T7f5
  Code Flash Free Space = 52690944
Reboot to load the new firmware.
ICX6610-48 Switch#write memory
ICX6610-48 Switch#reload
Are you sure? (enter 'y' or 'n'): y
Template note icon.png
Note: It takes a while to reboot because it will update the firmware of the second node. Please be patient.
ICX6610-48 Switch#show flash
Stack unit 1:
  Compressed Pri Code size = 5430491, Version:07.3.00jT7f1 (FCXS07300j.bin)
  Compressed Sec Code size = 6905002, Version:07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
  Compressed Boot-Monitor Image size = 370555, Version:07.3.02T7f5
  Code Flash Free Space = 52690944
Stack unit 2:
  Compressed Pri Code size = 5430491, Version 07.3.00jT7f1 (FCXS07300j.bin)
  Compressed Sec Code size = 6905002, Version 07.3.00fT7f3 (/foundry/FGS/os/FCXR07300f.bin)
  Compressed Boot-Monitor Image size = 370555, Version 07.3.02T7f5
  Code Flash Free Space = 52690944
Done!

Configure VLAN

VLANs provide a way of dividing up a switch (or stack of switches) into multiple, isolated switches (this is actually somewhat simplistic, but it gets the idea across). Traffic from one VLAN segment can not reach ports allocated to another VLAN, providing a useful layer of security.

Planning

We're creating three separate VLANs;
By default, all ports default to VID 1. If you want to improve security, you can leave all unused ports on VID 1. In this tutorial, we need to allocate all ports for use by other equipment.
Before you start, you need to decide how you want to assign physical ports on your switches to VLAN IDs. I like to do this by creating a table showing all the ports, label their external port numbers and logical numbers and then write in what will be plugged into each port. With this, it's fairly easy to mark what ports will be assigned to what VLANs.

Cabling a pair of ICX6450-24

In this example, we're showing how to cable up a pair of ICX6450-24 switches in a very typical configuration. It can drive two Anvil! systems along with the usual foundation pack.
The table below represents a pair of these stacked together.
an-switch01  
Stack   Back-Channel Network]] Storage Network Internet-Facing Network
X1 (1/2/1) X3 (1/2/3)   1 (1/1/1) 3 (1/1/3) 5 (1/1/5) 7 (1/1/7) 9 (1/1/9) 11 (1/1/11)   13 (1/1/13) 15 (1/1/15) 17 (1/1/17) 19 (1/1/19) 21 (1/1/21) 23 (1/1/23)
To an-switch02
X3
To an-switch02
X1
  an-a01n01
BCN - Link 1
an-a01n01
IPMI / Fencing
an-a02n01
BCN - Link 1
an-a02n01
IPMI / Fencing
an-striker01
BCN - Link 2
an-a01n01
SN - Link 1
  an-a02n01
SN - Link 1
an-a01n01
IFN - Link 1
an-a02n01
IFN - Link 1
an-striker01
IFN - Link 1
-- --
-- --   an-a01n02
BCN - Link 1
an-a01n02
IPMI / Fencing
an-a02n02
BCN - Link 1
an-a02n02
BCN - Link 1
-- an-a01n02
SN - Link 1
  an-a02n02
SN - Link 1
an-a01n02
IFN - Link 1
an-a02n02
IFN - Link 1
-- -- Uplink 1
X2 (1/2/2) X4 (1/2/4)   2 (1/1/2) 4 (1/1/4) 6 (1/1/6) 8 (1/1/8) 10 (1/1/10) 12 (1/1/12)   14 (1/1/14) 16 (1/1/16) 18 (1/1/18) 20 (1/1/20) 22 (1/1/22) 24 (1/1/24)
Unused   VID 100 VID 200 VID 300
 
an-switch02  
Stack   Back-Channel Network]] Storage Network Internet-Facing Network
X1 (2/2/1) X3 (2/2/3)   1 (2/1/1) 3 (2/1/3) 5 (2/1/5) 7 (2/1/7) 9 (2/1/9) 11 (2/1/11)   13 (2/1/13) 15 (2/1/15) 17 (2/1/17) 19 (2/1/19) 21 (2/1/21) 23 (2/1/23)
To an-switch01
X3
To an-switch01
X1
  an-a01n01
BCN - Link 2
an-pdu01 an-a02n01
BCN - Link 2
an-ups01 an-striker02
BCN - Link 1
an-a01n01
SN - Link 2
  an-a02n01
SN - Link 2
an-a01n01
IFN - Link 2
an-a02n01
IFN - Link 2
an-striker01
IFN - Link 2
-- --
-- --   an-a01n02
BCN - Link 2
an-pdu02 an-a02n02
BCN - Link 2
an-ups02 -- an-a01n02
SN - Link 2
  an-a02n02
SN - Link 2
an-a01n02
IFN - Link 2
an-a02n02
IFN - Link 2
-- -- Uplink 2
X2 (2/2/2) X4 (2/2/4)   2 (2/1/2) 4 (2/1/4) 6 (2/1/6) 8 (2/1/8) 10 (2/1/10) 12 (2/1/12)   14 (2/1/14) 16 (2/1/16) 18 (2/1/18) 20 (2/1/20) 22 (2/1/22) 24 (2/1/24)
Unused   VID 100 VID 200 VID 300

Cabling a pair of ICX6610-48

In this example, we're showing how to cable up a pair of ICX6610-48 switches in a rather unusual configuration. It is driving just one Anvil!, but that Anvil! is using 10 Gbps SFP+ links. The switches are going to be populated with non-Anvil! equipment.
What you will configure will, of course, totally vary. The specific ports aren't the point, the planning and implementation are.
The table below represents a pair of these stacked together.
an-switch01    
BCN SN IFN   Back-Channel Network Internet-Facing Network
X1 (1/2/1) X3 (1/2/3) X5 (1/2/5) X7 (1/2/7)   1 (1/1/1) 3 (1/1/3) 5 (1/1/5) 7 (1/1/7) 9 (1/1/9) 11 (1/1/11) 13 (1/1/13) 15 (1/1/15) 17 (1/1/17) 19 (1/1/19) 21 (1/1/21) 23 (1/1/23) 25 (1/1/25) 27 (1/1/27) 29 (1/1/29) 31 (1/1/31) 33 (1/1/33) 35 (1/1/35) 37 (1/1/37) 39 (1/1/39) 41 (1/1/41) 43 (1/1/43) 45 (1/1/45) 47 (1/1/47)
an-a05n01
BCN - Link 1
an-a05n01
SN - Link 1
an-a05n01
IFN - Link 1
    an-a05n01
BCN - Link 3
an-a05n01
IPMI / Fencing
an-striker01
BCN - Link 1
an-striker01
IPMI
        an-a05n01
IFN - Link 3
an-striker01
IFN - Link 1
                           
X2 (1/2/2) X4 (1/2/4) X6 (1/2/6) X8 (1/2/8)   2 (1/1/2) 4 (1/1/4) 6 (1/1/6) 8 (1/1/8) 10 (1/1/10) 12 (1/1/12) 14 (1/1/14) 16 (1/1/16) 18 (1/1/18) 20 (1/1/20) 22 (1/1/22) 24 (1/1/24) 26 (1/1/26) 28 (1/1/28) 30 (1/1/30) 32 (1/1/32) 34 (1/1/34) 36 (1/1/36) 38 (1/1/38) 40 (1/1/40) 42 (1/1/42) 44 (1/1/44) 46 (1/1/46) 48 (1/1/48)
an-a05n02
BCN - Link 1
an-a05n02
SN - Link 1
an-a05n02
IFN - Link 1
    an-a05n02
BCN - Link 3
an-a05n02
IPMI / Fencing
an-striker02
BCN - Link 1
          an-a05n02
IFN - Link 3
an-striker02
BCN - Link 1
                          Uplink 1
VID 100 VID 200 VID 300   VID 100 VID 300
 
an-switch02  
BCN SN IFN   Back-Channel Network Internet-Facing Network
X1 (2/2/1) X3 (2/2/3) X5 (2/2/5) X7 (2/2/7)   1 (2/1/1) 3 (2/1/3) 5 (2/1/5) 7 (2/1/7) 9 (2/1/9) 11 (2/1/11) 13 (2/1/13) 15 (2/1/15) 17 (2/1/17) 19 (2/1/19) 21 (2/1/21) 23 (2/1/23) 25 (2/1/25) 27 (2/1/27) 29 (2/1/29) 31 (2/1/31) 33 (2/1/33) 35 (2/1/35) 37 (2/1/37) 39 (2/1/39) 41 (2/1/41) 43 (2/1/43) 45 (2/1/45) 47 (2/1/47)
an-a05n01
BCN - Link 2
an-a05n01
SN - Link 2
an-a05n01
IFN - Link 2
    an-pdu01 an-ups01 an-striker02
BCN - Link 2
an-striker02
IPMI
an-pdu03         an-striker02
IFN - Link 2
                           
X2 (2/2/2) X4 (2/2/4) X6 (2/2/6) X8 (2/2/8)   2 (2/1/2) 4 (2/1/4) 6 (2/1/6) 8 (2/1/8) 10 (2/1/10) 12 (2/1/12) 14 (2/1/14) 16 (2/1/16) 18 (2/1/18) 20 (2/1/20) 22 (2/1/22) 24 (2/1/24) 26 (2/1/26) 28 (2/1/28) 30 (2/1/30) 32 (2/1/32) 34 (2/1/34) 36 (2/1/36) 38 (2/1/38) 40 (2/1/40) 42 (2/1/42) 44 (2/1/44) 46 (2/1/46) 48 (2/1/48)
an-a05n02
BCN - Link 2
an-a05n02
SN - Link 2
an-a05n02
IFN - Link 2
    an-pdu02 an-ups02 an-striker02
BCN - Link 2
  an-pdu04         an-striker02
BCN - Link 2
                          Uplink 2
VID 100 VID 200 VID 300   VID 100 VID 300

Understanding Brocade Logical Port Numbers

Brocade uses the follow scheme for naming their ports:
  • stack ID/module/port
The Stack ID is simply the integer representing the ID number shown when you run 'show stack'.
The module number is static across all switches. They are:
  • 1: Standard RJ-45 1 Gbps copper ports.
  • 2: Ports used for stacking. Typically these are only used for stacking.
  • 3: The SFP+ fiber or copper ports that normally run at 1 Gbps but can be licensed to run at 10 Gbps.
The port number is the simple integer representing the port. This is the number found above or below the physical port on the switch.
You see these x/y/z numbers in the table above, and they will be the method used below to identify ports and port ranges.

Forming the VLANs

To start, lets take a look at the current VLAN configuration.
ICX6610-48 Switch#configure terminal
ICX6610-48 Switch(config)#show vlan
Total PORT-VLAN entries: 1
Maximum PORT-VLAN entries: 64
 
Legend: [Stk=Stack-Id, S=Slot]
Not much!
ICX6610-48 Switch(config)#vlan 100 name bcn
The BCN spans SFP ports 1 and 2 (1/3/1 to 1/3/1, 2/3/1 to 2/3/1) and copper ports 1 through 16 (1/1/1 to 1/1/16, 2/1/1 to 2/1/16) will be assigned to this VLAN. We can do this in one command.
ICX6610-48 Switch(config-vlan-100)#untag ethernet 1/3/1 to 1/3/2 ethernet 2/3/1 to 2/3/2 ethernet 1/1/1 to 1/1/16 ethernet 2/1/1 to 2/1/16
Added untagged port(s) ethe 1/1/1 to 1/1/16 ethe 1/3/1 to 1/3/2 ethe 2/1/1 to 2/1/16 ethe 2/3/1 to 2/3/2 to port-vlan 100.
The SN spans just four ports, all of which are on the SFP+ ports. They are 1/3/3 to 1/3/4 and 2/3/3 to 2/3/4.
ICX6610-48 Switch(config-vlan-100)#vlan 200 name sn
ICX6610-48 Switch(config-vlan-200)#untag ethernet 1/3/3 to 1/3/4 ethernet 2/3/3 to 2/3/4
Added untagged port(s) ethe 1/3/3 to 1/3/4 ethe 2/3/3 to 2/3/4 to port-vlan 200.
Finally, the biggest VLAN. We're going to allocate the last four SFP+ ports on both switch and copper ports 17 through 48 on both as well.
ICX6610-48 Switch(config-vlan-200)#vlan 300 name ifn
ICX6610-48 Switch(config-vlan-300)#untag ethernet 1/3/5 to 1/3/8 ethernet 2/3/5 to 2/3/8 ethernet 1/1/17 to 1/1/48 ethernet 2/1/17 to 2/1/48
Added untagged port(s) ethe 1/1/17 to 1/1/48 ethe 1/3/5 to 1/3/8 ethe 2/1/17 to 2/1/48 ethe 2/3/5 to 2/3/8 to port-vlan 300.
Done! Let's see what it looks like now:
ICX6610-48 Switch(config-vlan-300)#exit
ICX6610-48 Switch(config)#show vlan
Total PORT-VLAN entries: 4
Maximum PORT-VLAN entries: 64
 
Legend: [Stk=Stack-Id, S=Slot]
 
PORT-VLAN 1, Name DEFAULT-VLAN, Priority level0, Spanning tree On
 Untagged Ports: None
   Tagged Ports: None
   Uplink Ports: None
 DualMode Ports: None
 Mac-Vlan Ports: None
     Monitoring: Disabled
PORT-VLAN 100, Name bcn, Priority level0, Spanning tree On
 Untagged Ports: (U1/M1)   1   2   3   4   5   6   7   8   9  10  11  12 
 Untagged Ports: (U1/M1)  13  14  15  16 
 Untagged Ports: (U1/M3)   1   2 
 Untagged Ports: (U2/M1)   1   2   3   4   5   6   7   8   9  10  11  12 
 Untagged Ports: (U2/M1)  13  14  15  16 
 Untagged Ports: (U2/M3)   1   2 
   Tagged Ports: None
   Uplink Ports: None
 DualMode Ports: None
 Mac-Vlan Ports: None
     Monitoring: Disabled                                         
PORT-VLAN 200, Name sn, Priority level0, Spanning tree On
 Untagged Ports: (U1/M3)   3   4 
 Untagged Ports: (U2/M3)   3   4 
   Tagged Ports: None
   Uplink Ports: None
 DualMode Ports: None
 Mac-Vlan Ports: None
     Monitoring: Disabled
PORT-VLAN 300, Name ifn, Priority level0, Spanning tree On
 Untagged Ports: (U1/M1)  17  18  19  20  21  22  23  24  25  26  27  28 
 Untagged Ports: (U1/M1)  29  30  31  32  33  34  35  36  37  38  39  40 
 Untagged Ports: (U1/M1)  41  42  43  44  45  46  47  48 
 Untagged Ports: (U1/M3)   5   6   7   8 
 Untagged Ports: (U2/M1)  17  18  19  20  21  22  23  24  25  26  27  28 
 Untagged Ports: (U2/M1)  29  30  31  32  33  34  35  36  37  38  39  40 
 Untagged Ports: (U2/M1)  41  42  43  44  45  46  47  48 
 Untagged Ports: (U2/M3)   5   6   7   8 
   Tagged Ports: None
   Uplink Ports: None
 DualMode Ports: None
 Mac-Vlan Ports: None
     Monitoring: Disabled
Perfectly perfect. Save the changes and then we're done.
ICX6610-48 Switch(config)#write memory
Write startup-config done.
 
Automatic copy to member units:  2
Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.

Changing a Port's VLAN Assignment

In order to change a port from one VLAN to another, it must first to untagged as VLAN ID 1, then it can be re-assigned to the new VLAN ID.
### (config-vlan-200) no untag ethernet 2/1/15 to 2/1/24
### (config-vlan-200) show vlan
Template note icon.png
Note: A port in VID 1 will simply change to the newly assigned VID. Ports in other VIDs need to be reset with no untag ... before reconfiguring for the new VLAN.

Pseudo Stacking on ICX6430-C12

To share one uplink between multiple VLANs (to act like a stack);
config terminal
an-s05(config)#vlan 100
an-s05(config-vlan-100)#tagged ethernet 1/2/1
Added tagged port(s) ethe 1/2/1 to port-vlan 100.
an-s05(config-vlan-100)#vlan 200
an-s05(config-vlan-200)#tagged ethernet 1/2/1
Added tagged port(s) ethe 1/2/1 to port-vlan 200.
an-s05(config-vlan-200)#vlan 300
an-s05(config-vlan-300)#tagged ethernet 1/2/1
Added tagged port(s) ethe 1/2/1 to port-vlan 300.
To prevent switch loops when plugging in both C2.
an-s05(config-vlan-300)#spanning-tree rstp

Trunking

Passive Trunk

This is used when the connected switch does not support LACP.
Template note icon.png
Note: Configure with only one cable connected into the trunk ports.
# config terminal
## (config) trunk ethernet 1/1/24 ethernet 2/1/24
 
Trunk will be created in next trunk deploy.
 
## (config) trunk deploy
## (config) write memory

Active Trunk

This is used if you can create an LACP on the client's switch.
Template note icon.png
Note: Configure with only one cable connected into the trunk ports.
# config terminal
## (config) interface ethernet 1/1/23 ethernet 2/1/23
## (config-mif-1/1/23,2/1/23) link-aggregate active
## exit
## show link-aggregate
 
System ID: 748e.f8ff.cf1c
Long  timeout: 90, default: 90
Short timeout: 3, default: 3
Port  [Sys P] [Port P] [  Key ] [Act][Tio][Agg][Syn][Col][Dis][Def][Exp][Ope]
1/1/23      1        1      482   Yes   S   Agg  Syn  Col  Dis  Def  No   Dwn
2/1/23      1        1      482   Yes   S   Agg  Syn  Col  Dis  Def  No   Dwn

Key Management

To get a license, you must purchase the license from a Brocade reseller. With it, you will get a spreadsheet containing a TRANSACTION KEY.
To convert this into a loadable license file, you will need to get the switch's 'LID', then create an account on "My Brocade". You can then combine the LID and the TRANSACTION KEY and Brocade will email you the license key.
To get the LID;
ICX6610-48 Switch#show version
  Copyright (c) 1996-2013 Brocade Communications Systems, Inc.
    UNIT 1: compiled on May 10 2013 at 16:48:26 labeled as FCXS07300f
                (5370497 bytes) from Primary /foundry/FGS/os/FCXS07300f.bin
        SW: Version 07.3.00fT7f1 
    UNIT 2: compiled on May 10 2013 at 16:48:26 labeled as FCXS07300f
                (5370497 bytes) from Primary /foundry/FGS/os/FCXS07300f.bin
        SW: Version 07.3.00fT7f1 
  Boot-Monitor Image size = 370555, Version:07.3.02T7f5 (grz07302)
  HW: Stackable ICX6610-48
==========================================================================
UNIT 1: SL 1: ICX6610-48 48-port Management Module
         Serial  #: xxxxxxxxxxx
         License: BASE_SOFT_PACKAGE   (LID: yyyyyyyyyyy)
         P-ENGINE  0: type E02B, rev 01
         P-ENGINE  1: type E02B, rev 01
==========================================================================
UNIT 1: SL 2: ICX6610-QSFP 10-port 160G Module
==========================================================================
UNIT 1: SL 3: ICX6610-8-port Dual Mode(SFP/SFP+) Module
==========================================================================
UNIT 2: SL 1: ICX6610-48 48-port Management Module
         Serial  #: aaaaaaaaaaa
         License: BASE_SOFT_PACKAGE   (LID: bbbbbbbbbbb)
         P-ENGINE  0: type E02B, rev 01                           
         P-ENGINE  1: type E02B, rev 01
==========================================================================
UNIT 2: SL 2: ICX6610-QSFP 10-port 160G Module
==========================================================================
UNIT 2: SL 3: ICX6610-8-port Dual Mode(SFP/SFP+) Module
==========================================================================
  800 MHz Power PC processor 8544E (version 0021/0023) 400 MHz bus
65536 KB flash memory
  512 MB DRAM
STACKID 1  system uptime is 1 days 17 hours 8 minutes 17 seconds 
STACKID 2  system uptime is 22 hours 36 minutes 24 seconds 
The system : started=warm start  reloaded=by "reload"
My stack unit ID = 1, bootup role = active

Navigating Brocade's Website

With the TRANSACTION KEY and LID, and having logged into Brocade Software Portal;
  • Hover over the top-left 'License Management' button. A drop-down menu will appear. Hover over 'Brocade IP/ADP'. Another pop-out menu will appear, click on 'License Generation with Transaction Key'.
  • A form will appear. Fill it our as instructed. Check to accept the EULA and then click 'Add'.
    • IF YOU ARE ADDING TWO LICENSES TO ONE SWITCH:
    • Fill out the LID and Transaction key for the next license, again accept the EULA and click 'Add' again.
  • Once all licenses for the specified switch are added, click on 'Generate'.
  • If all was well, you will be shown a summary and an email with the license will be emailed to you.
Repeat as needed for each switch.

Installing Keys

Once you get the license file from Brocade, copy the key to the root of your TFTP server (/var/lib/tftpboot/ on EL6).
Note the LID number and which stack ID. In this case, I renamed the license files so that an-switch01_XXXXXXXXXXX.xml, where XXXXXXXXXXX is the switch's LID. In the example below, I will load two licenses, one for either switch in the stack.
ICX6610-24 Switch#copy tftp license 10.255.255.254 an-switch01_XXXXXXXXXXX.xml unit 1
Flash Memory Write (8192 bytes per dot) .
Copy Software License from TFTP to Flash Done.
T=1d20h6m27.7: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1,
ICX6610-24 Switch#copy tftp license 10.255.255.254 an-switch02_XXXXXXXXXXX.xml unit 2
Flash Memory Write (8192 bytes per dot) .
Copy Software License from TFTP to Flash Done.
 
Copy software license to stack unit 2 success
Flash Memory Write (8192 bytes per dot) .
T=1d20h7m50.1: Election, was active, no change, ID=1, pri=128, 2U(1-2), A=u1, nbr#=1 1,
ICX6610-24 Switch#show license
Index      License Name              Lid          License Type    Status     License Period  License Capacity  
Stack unit 1:
1          ICX6610-10G-LIC-POD       xxxxxxxxxxx  Normal          Active     Unlimited                  8 
Stack unit 2:
1          ICX6610-10G-LIC-POD       aaaaaaaaaaa  Normal          Active     Unlimited                  8
write memory
Repeat as needed.

Enable 10 Gbps Ports

After installing license files to upgrade the eight 1 Gbps SFP+ ports to run as 10 Gbps, we need to actually enable the ports. This may seem silly, but consider that the upgrades are sold in lots of 4-ports at a time. This step would allow you to specify which four ports were upgraded. In our case, we upgraded them all.
ICX6610-48 Switch#config terminal
ICX6610-48 Switch(config)#interface ethernet 1/3/1 to 1/3/8
ICX6610-48 Switch(config-mif-1/3/1-1/3/8)#speed-duplex 10g-full
This will take a minute, please wait.
ICX6610-48 Switch(config-mif-1/3/1-1/3/8)#interface ethernet 2/3/1 to 2/3/8
ICX6610-48 Switch(config-mif-2/3/1-2/3/8)#speed-duplex 10g-full
ICX6610-48 Switch(config-mif-2/3/1-2/3/8)#exit

If you (accidentally) use a 1 Gbps SFP+ cable, the upgrade will likely throw an error like the one below:
U2-MSG: INFO: 2/3/4: optics <-> speed mismatch. Replace with SFP+ to enable link.
U2-MSG: INFO: 2/3/4: optics <-> speed mismatch. Replace with SFP+ to enable link.
You can reduce the port speed to make it work (albeit at 1 Gbps):
ICX6610-48 Switch(config-mif-1/3/1-1/3/8)#interface ethernet 2/3/4
ICX6610-48 Switch(config-if-e10000-2/3/4)#speed-duplex 1000-full-master
When done, save your changes.
ICX6610-48 Switch(config)#write memory
Write startup-config done.
 
Automatic copy to member units:  2
ICX6610-48 Switch(config)#Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.

Deleting Keys

If you need to remove a key (ie: replacing a demo license), you can do so thusly:
ICX6610-24 Switch#license delete unit 1 index 1
 
ICX6610-24 Switch#show license
License record empty

Replacing a Switch

Template warning icon.png
Warning: The switch that is the stack master will overwrite the configuration of the stack slave. So be sure to flash the firmware to match the existing switch, license the ports if needed and enable stacking on the replacement switch while it is stand-alone. Power it off, plug in the stack cables and then apply power. When it boots, it's config should be replaced with the good switch's configuration. To be safe, in an Anvil!, withdraw a node before reforming the stack.
Template warning icon.png
Warning: You must contact Brocade to move the licenses!
If a switch needs to be replaced, we may need to "de-license" the old switch.
Call Brocade support (1-800-752-8061) and use the case number the switch was replaced under. Confirm with them the LID of the switch being replaced (the one that the license will be removed from) and the LID of the new/replacement switch.
With the switch being returned, there is no need to prove the old license is removed as you will be returning the switch. If you will NOT be returning the switch, then you will need to provide a show license before and after deleting the old license in order for the license to be reissued. This is a rare case and the Brocade technician will walk you through the process should it be required.
They will email you the replacement license, at which point you will license the replacement switch as if it were a new switch.
Template note icon.png
Note: Depending your email client, you may need to request the XML license file be attached separately.

Checking the Firmware

Before you proceed, make sure the Firmware is the same version as the stack master. If not, upgrade (or downgrade) the RMAed switch to match.

Licensing the Switch

Once you have the XML file, proceed from here.

Adding the Switch to the Stack

For this step, we want to enable stacking on the new switch and nothing more.
stack enable
Enable stacking. This unit actively participates in stacking
stacking is enable. optical monitoring for stacking ports 1/2/1, 1/2/6 is not available.
write memory
Write startup-config done.
 
ICX6610-48 Switch(config)#Flash Memory Write (8192 bytes per dot) .
Flash to Flash Done.
Template note icon.png
Note: In the example below, switch 1 is being replaced.
At this point, switch to the production switch (which ever isn't being replaced). Connect the newly flashed and licensed replacement switch and you should see the configuration automatically upload to the newly replaced switch.
ICX6610-48 Switch#T=4d4h15m31.2: Election, was active, no change, ID=2, pri=128, 2U(1-2), A=u2, nbr#=1 0, 
T=4d4h15m32.2: Election, was active, no change, ID=2, pri=128, 2U(1-2), A=u2, nbr#=1 0, 
Detect stack unit 1 has different startup config flash, will synchronize it
T=4d4h15m34.0: Election, was active, no change, ID=2, pri=128, 2U(1-2), A=u2, nbr#=1 1, 
Detect stack unit 1 has different startup config flash, will synchronize it
reset unit 1: jumbo mismatch. Act u2: 1, Mem u1: 0
reset unit 1: jumbo mismatch. Act u2: 1, Mem u1: 0
Unit 2 loses all neighbors.
Active unit 2 deletes u1 but keeps its static config.
Some time passes:
T=4d4h18m52.3: Election, was active, no change, ID=2, pri=128, 2U(1-2), A=u2, nbr#=1 1, 
Detect stack unit 1 has different startup config flash, will synchronize it
Done hot swap: active controller unit 2 sets unit 1 to Ready.
Synchronize startup config to stack unit 1
Flash Memory Write (8192 bytes per dot) .
Assigned unit 1 to be standby
start running config sync
Running config sync to standby is complete
At this point, recovery is complete.

Unconfigure Stack

If you boot a stacked switch on it's own, you will not have normal access to the switch configuration.
MEMBER]local-1@ICX6610-48 Switch>enable
No password has been assigned yet...
[MEMBER]local-1@ICX6610-48 Switch#
To clear the stack config and restore the switch to standard mode, run:
stack unconfigure clean
This unit will delete all config files and boot up as a clean unit. Are you sure? (enter 'y' or 'n'): y
Remove startup config and stacking files. Will reload as a clean unit
[MEMBER]local-1@ICX6610-48 Switch#HRebooting(1)...

Multicast Config

ICX6610-24 Switch#config terminal 
ICX6610-24 Switch(config)#vlan 300
ICX6610-24 Switch(config-vlan-300)#multicast passive 
ICX6610-24 Switch(config-vlan-300)#multicast version 2
Done

Resetting Lost Password

If you've lost the system password, you will need physical access to the switch.
Template note icon.png
Note: If you can't sit at your computer and press the reset button directly, ask someone to help with this next step as the timing is short.
On the front of the switch will be a small "Reset" switch. To press this, you will need a very thin object in order to press the button, like a small paper clip, needle or so on.
During the boot process, press b when you see the Enter 'b' to stop at boot monitor: prompt.
Enter 'b' to stop at boot monitor:  0 
ICX64XX-boot>> no password
OK! Skip password check when the system is up.
ICX64XX-boot>> boot system flash primary
Usage:
boot    - boot default, i.e., run 'bootcmd'
 
ICX64XX-boot>> boot_primary
Booting image from Primary
## Booting image at 00007fc0 ...
   Created:      2013-04-27   3:19:57 UTC
   Data Size:    10552120 Bytes = 10.1 MB
   Load Address: 00008000
   Entry Point:  00008000
   Verifying Checksum ... OK
OK
On next boot, you will be able to log into the switch without a password.

Reset to Factory Defaults

Template note icon.png
Note: This will erase any loaded licenses. If you have loaded licenses, be sure you have them backed up before proceeding.
At the command prompt, do:
SHESW11#erase startup-config 
Erase startup-config Done.
dhcp server lease database is also removed
Template warning icon.png
Warning: Do not write memory! This will reload the running configuration back onto the system.
SHESW11#reload
Are you sure? (enter 'y' or 'n'): 
Sent SIGKILL to all processes
Requesting system reboot
Restarting syste
On the next boot, you should have an as-new system.

SNMP

ICX-6430-C12

To enable read-write access of MIB data;
an-s06(config)#snmp-server community public rw

Notes

Port numbering syntax is:
//
Module numbering;
  • 1; Copper 1 Gbit
  • 2; Fibre stack
  • 3; 10 Gbps fibre
View the port status:
ICX6610-48 Switch(config)#show interfaces brief
 
Port    Link    State   Dupl Speed Trunk Tag Pvid Pri MAC            Name      
1/1/1   Down    None    None None  None  No  1    0   cc4e.24b9.4b74          
1/1/2   Down    None    None None  None  No  1    0   cc4e.24b9.4b75          
1/1/3   Down    None    None None  None  No  1    0   cc4e.24b9.4b76          
1/1/4   Down    None    None None  None  No  1    0   cc4e.24b9.4b77          
1/1/5   Down    None    None None  None  No  1    0   cc4e.24b9.4b78          
1/1/6   Down    None    None None  None  No  1    0   cc4e.24b9.4b79          
1/1/7   Down    None    None None  None  No  1    0   cc4e.24b9.4b7a          
1/1/8   Down    None    None None  None  No  1    0   cc4e.24b9.4b7b          
1/1/9   Down    None    None None  None  No  1    0   cc4e.24b9.4b7c          
1/1/10  Down    None    None None  None  No  1    0   cc4e.24b9.4b7d          
1/1/11  Down    None    None None  None  No  1    0   cc4e.24b9.4b7e          
1/1/12  Down    None    None None  None  No  1    0   cc4e.24b9.4b7f          
1/1/13  Down    None    None None  None  No  1    0   cc4e.24b9.4b80          
1/1/14  Down    None    None None  None  No  1    0   cc4e.24b9.4b81          
1/1/15  Down    None    None None  None  No  1    0   cc4e.24b9.4b82          
1/1/16  Down    None    None None  None  No  1    0   cc4e.24b9.4b83          
1/1/17  Down    None    None None  None  No  1    0   cc4e.24b9.4b84          
1/1/18  Down    None    None None  None  No  1    0   cc4e.24b9.4b85          
1/1/19  Down    None    None None  None  No  1    0   cc4e.24b9.4b86          
1/1/20  Down    None    None None  None  No  1    0   cc4e.24b9.4b87          
1/1/21  Down    None    None None  None  No  1    0   cc4e.24b9.4b88          
1/1/22  Down    None    None None  None  No  1    0   cc4e.24b9.4b89          
1/1/23  Down    None    None None  None  No  1    0   cc4e.24b9.4b8a          
1/1/24  Down    None    None None  None  No  1    0   cc4e.24b9.4b8b          
1/1/25  Down    None    None None  None  No  1    0   cc4e.24b9.4b8c          
1/1/26  Down    None    None None  None  No  1    0   cc4e.24b9.4b8d          
1/1/27  Down    None    None None  None  No  1    0   cc4e.24b9.4b8e          
1/1/28  Down    None    None None  None  No  1    0   cc4e.24b9.4b8f          
1/1/29  Down    None    None None  None  No  1    0   cc4e.24b9.4b90          
1/1/30  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b91          
1/1/31  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b92          
1/1/32  Down    None    None None  None  No  1    0   cc4e.24b9.4b93          
1/1/33  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b94          
1/1/34  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b95          
1/1/35  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b96          
1/1/36  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b97          
1/1/37  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b98          
1/1/38  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b99          
1/1/39  Down    None    None None  None  No  1    0   cc4e.24b9.4b9a          
1/1/40  Down    None    None None  None  No  1    0   cc4e.24b9.4b9b          
1/1/41  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b9c          
1/1/42  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b9d          
1/1/43  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4b9e          
1/1/44  Down    None    None None  None  No  1    0   cc4e.24b9.4b9f          
1/1/45  Down    None    None None  None  No  1    0   cc4e.24b9.4ba0          
1/1/46  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4ba1          
1/1/47  Down    None    None None  None  No  1    0   cc4e.24b9.4ba2          
1/1/48  Up      Forward Full 1G    None  No  1    0   cc4e.24b9.4ba3          
1/2/1   Up      Forward Full 40G   None  No  N/A  0   cc4e.24b9.4ba5          
1/2/2   Up      Forward Full 10G   None  No  N/A  0   cc4e.24b9.4ba6          
1/2/6   Up      Forward Full 40G   None  No  N/A  0   cc4e.24b9.4ba7          
1/2/7   Up      Forward Full 10G   None  No  N/A  0   cc4e.24b9.4ba8          
1/3/1   Down    None    None None  None  No  1    0   cc4e.24b9.4ba9          
1/3/2   Up      Forward Full 10G   None  No  1    0   cc4e.24b9.4baa          
1/3/3   Down    None    None None  None  No  1    0   cc4e.24b9.4bab          
1/3/4   Down    None    None None  None  No  1    0   cc4e.24b9.4bac          
1/3/5   Down    None    None None  None  No  1    0   cc4e.24b9.4bad          
1/3/6   Up      Forward Full 10G   None  No  1    0   cc4e.24b9.4bae          
1/3/7   Down    None    None None  None  No  1    0   cc4e.24b9.4baf          
1/3/8   Down    None    None None  None  No  1    0   cc4e.24b9.4bb0          
mgmt1   Down    None    None None  None  No  None 0   cc4e.24b9.4b74
 







Saturday, March 5, 2016

Brocade 65xx series and airflow

Original text from:  http://www.erwinvanlonden.net/2014/02/brocade-65xx-series-and-airflow/
This is important!! Now, you would think that when you look at the weather channel and the person tells you there is a wind coming from the North the direction is from North to South. This could be interpreted somewhat different when he or she tells you there is a “northerly” wind. Does the later mean it’s coming from the North or is it going to the North. The same is now true for Brocade 65xx series switches. The 6505/6510 have a different interpretation of how the wind blows than the 6520 series. Is it moving forward or reverse, is it coming from the front or back and on which side is the intake and/or exhaust and which spare-part do you need to order in case one fails, xx-F or xx-R. If you order the wrong one the switch will tell your this after which it will shut down. Whoops. The documentation also shows some confusion around the PS acronym. Is it now related to the airflow, in which case it stands for Port-Side, or does it mean Power Supply when a FRU is meant?

It looks like a set of different engineers have been using the above terminology and got confused themselves therefor making assumptions and this didn’t really fan out well. I’m sure they will correct it in the near future with some newer code and adjust the documentation.
So here’s how it is.
On the 6505 and the 6510:


6510 airflow back-to-front
When the intake is from the rear and the exhaust is on the port-side you should see the following:
  • Orange “I” sticker on the power supply/fan FRU
  • Power supply spare part number should end with -R
  • The powersupply/fan FRU is XBR-5100-0001
  • When looking in the chassisshow output you should see “Forward”
    • FAN Unit: X
    • Fan Direction: Forward
  • No spare-part number in any of the logs
  • * the 5100 in the PS/fan FRU is the same as for the 5100
When the intake is from the front and the exhaust is at the back:
  • Green “E” sticker on the powersupply/fan FRU’s
  • Chassis spare partnumer ends with a -F
  • Power supply spare part number end with an -F
  • FRU partnumber is XBR-6510-0001
  • The chassisshow output mentions “Reverse”
On the 6520 the above is the other way around.

Intake from the front and exhaust at the back.

  • Green “E” sticker on the powersupply/fab FRU’s
  • -F is in the chassis spare-part number
  • Chassisshow shows ‘Forward”.
  • The powersupply spare FRU is XBR-1100WPSAC-F
  • The fan FRU partnumer is XBR-FAN-80-F
Intake from the rear and exhaust at the front.
  • Orange “I” sticker on powersupply and fan FRU’s
  • Sparepart number end in -R
  • The chassisshow output shows ‘Reverse”
  • Powersupplu spare part is XBR-1100WPSAC-R
  • The fan spare part number is XBR-FAN-80-R
As mentioned, this might change in the future when brocade is modifying FOS to show the correct airflow in the logs and CLI chassisshow output. I certainly hope there won’t be more platforms where this happens.
It doesn’t happen often that a powersupply or fan fails. I’ve been working with Brocade switches for more than 15 years and I’ve seen switches with powersupplies and fans working for over 5 years. (I replaced it with newer gear so I couldn’t determine for how long it would last in the end.)  Not really a problem but this is just to make you aware of the discrepancy.

Tuesday, November 24, 2015

Monitoring Dell Servers in HP Systems Insight Manager

Original text from: http://en.community.dell.com/techcenter/systems-management/w/wiki/3891.monitoring-dell-servers-in-hp-systems-insight-manager
 
 This post explains the details of managing Dell Servers with HP Systems Insight Manager(HPSIM) and enabling SNMP Traps support. The server MIB files “10892.mib” and “dcstorag.mib” can be used for monitoring the Dell Servers in an environment managed by HPSIM.
Managed Node Pre-Requisites
         Installing the OpenManage Server Administrator
            The Dell Server should be installed with the Server Administrator Software to enable the monitoring. The Server Administrator software comes with the installation DVD and the details for the installation and configuration of the OpenManage Server Administrator is available in support.dell.com manuals.
      Configuring the SNMP Service
            The SNMP Service needs to be configured in the Server to enable the SNMP communication between the Dell Server and HPSIM. To enable the traps to be forwarded to the HP SIM server the SNMP Trap destination needs to be configured properly with the HP SIM Server IP Address. The details for the SNMP configuration configuration is available in the Server Administrator documents in support.dell.com.
 The current latest version can be downloaded from support.dell.com :
        @ http://support.dell.com/support/edocs/software/svradmin/7.1/en/index.htm
 Loading the Dell MIBs in HPSIM
            The Dell Server MIB files are available with the Server Administrator DVD and also the MIBs can be downloaded from support.dell.com.
  • Uploading he MIBs:
                 Uploading the MIBs is simply copying the MIBs from the downloaded folder to the \Program Files\HP\Systems Insight Manager\mibs folder
  1.  Copy “10892.mib” to \Program Files\HP\Systems Insight Manager\mibs
  2.  Copy “dcstorag.mib” to \Program Files\HP\Systems Insight Manager\mibs
             Note - As HPSIM generates an error when a MIB has a filename that contains only    numbers, rename “10892.mib” to “new10892.mib”, and for consistency also rename to “dcstorag.mib” to “newdcstorag.mib”.
  • Compiling the MIBs:
 The MIBs needs to be compiled to generate the intermediate .cfg file which can be used to register the MIBs in HP SIM.
  1. Open a command window (cmd.exe)
  2.  Change the working directory to \Program Files\HP\Systems Insight Manager\mibs.
  3. Enter the command “mcompile new10892.mib”. The MIB should compile and return the message “Mib Compilation completed successfully”.
  4. Enter the command “newdcstorag.mib”. The MIB should compile and return the message “Mib Compilation completed successfully”.
  • Registering the MIBs:
Register the Server MIB files as follows:
  1. Enter the command “mxmib -a new10892.cfg”. The MIB should register and return the message “COMMAND COMPLETED SUCCESSFULLY”.
  2. Enter the command “mxmib -a newdcstorag.cfg”. The MIB should register and return the message “COMMAND COMPLETED SUCCESSFULLY”.
 HPSIM – System Type Manager
                The System Type Manager is used to define the rules to identify the different systems in HP SIM. The steps used to configure the System Type Manager to recognize a Dell Server are as follows:
 Dell Windows Server
  1. Login to HPSIM.
  2. Select Options ‐> Manage System Types.
  3. Click the New… button. The New Rule pane will open below.
  4. Beside System object identifier click the Retrieve from system… button. The Retrieve from system pane will appear below the current pane.
  5. Enter the hostname or IP address of the target Dell system in the Target hostname or IP address text box.
  6. Click Get Response. Note that the response value of “1.3.6.1.4.1.311.1.1.3.1.2” is displayed below.
      • Figure 1
  7. Click the OK button to accept this value and return to the New rule pane.
  8. Beside MIB variable object identifier enter the OID for the Server MIB Attribute “systemManagementSoftwareName” value as “.1.3.6.1.4.1.674.10892.1.100.1”.
      • Figure 2
  9. Beside Object Value click on “Retrieve from System”
  10. Click Get Response. Note that the response value of “Server Administrator” is displayed below. This is the OpenManage Server Administrator software name retrieved from the Dell Server.
      • Figure 3
  11. Click the OK button to accept this value and return to the New rule pane.
  12. Beside Compare rule select Match.
  13. Beside System Type select Server.
  14. Beside Subtype select “Dell”.
  15. Beside Product model enter “Dell Windows Server”.
  16. Leave the Custom management page field blank and click the OK button.
 Dell Linux Server
  1. Login to HPSIM.
  2. Select Options ‐> Manage System Types.
  3. Click the New… button. The New Rule pane will open below.
  4. Beside System object identifier click the Retrieve from system… button. The Retrieve from system pane will appear below the current pane.
  5. Enter the hostname or IP address of the target Dell system in the Target hostname or IP address text box.
  6. Click Get Response. Note that the response value of “1.3.6.1.4.1.8072.3.2.10” is displayed below.
      • Figure 4 
  7. Click the OK button to accept this value and return to the New rule pane.
  8. Beside MIB variable object identifier enter the OID for the Server MIB Attribute “systemManagementSoftwareName” value as “.1.3.6.1.4.1.674.10892.1.100.1”.
  9. Beside Object Value click on “Retrieve from System”
  10. Click Get Response. Note that the response value of “Server Administrator” is displayed below. This is the OpenManage Server Administrator software name retrieved from the Dell Server.
  11. Click the OK button to accept this value and return to the New rule pane.
  12. Beside Compare rule select Match.
  13. Beside System Type select Server.
  14. Beside Subtype select “Dell”.
  15. Beside Product model enter “Dell Linux Server”.
  16. Leave the Custom management page field blank and click the OK button.
 Discovering Dell Servers
Once the Dell Server system type has been configured in the HP SIM, the Dell Servers can be properly discovered in HP SIM.

  • Global Protocol Settings:
 The SNMP settings can be changed as follows:

  • Click Options ‐> Protocol Settings ‐> Global Protocol Settings. The Global Protocol Settings window will appear.
      • Figure 5
  • Scroll down to the Default SNMP settings section and click on “Global Credentials” and Verify that the required community strings is configured and click on OK button to save the changes.
    • Figure 6

  • Discovering Dell Servers:

    • Click Options ‐> Discovery. The Discovery summary page will be displayed.
      • Figure 7

    • Click on New button, the Discovery options page will be shown.
    • Select the Discovery option “Discover a Single System” and enter the name for the discovery option and enter the IPAddress of the Dell Server.     Note – Also the Group discovery can be used to discover multiple servers.
      • Figure 8

    • Click on Save button to save and accept the changes.
              i.        Once the discovery rule is saved, Click on “Run Now” option to execute the discovery Rule. The Discovered Dell Server will be shown as
      • Figure 9

             ii.        The “Tools and Links” tab contains the link to launch the OpenManage Sever Administrator Console for Dell Servers.
      • Figure 10

            iii.        The Events tab will List the associated events with the corresponding Dell Server.
      • Figure 11

  • Testing Dell Server SNMP Traps:

    • Log on to Dell Server OpenManage Server Administrator console by clicking on the “openmanage” link from “Tools and Links” tab.
    • Navigate to the Temperature page in Main System under Server Module in the left-side navigation tree
      • Figure 12

    • Click on the “System Board Ambient Temperature” in the right-side navigation pane.
    • The Properties page tab will be displayed and select “Set to Values” option and set a value higher than the current Temperature reading to simulate the Warning alert for Temperature.
      • Figure 13

 
    • Click on Apply option to save the changes and verify that the Temperature status has been changed to Warning.
      • Figure 14

    • Navigate to the Events Tab in the HP SIM and the Temperature Alert should be shown in the Events page.
      • figure 15
    The Server Administrator SNMP Traps details are documented in the Message Reference guide and can be downloaded from support.dell.com.
Appendix
 MIB Files
#
MIB
MIB Filename
Description
1
Server Administrator Instrumentation MIB
10892.mib
The Server Administrator Instrumentation MIB provides
instrumentation data that allows you to monitor the health of a system with
SNMP management applications. It provides:
• Information about the status of temperatures, power supplies, voltages,
currents, fans, and memory at key points in the system
• Rapid access to detailed fault and performance information gathered by
industry standard systems management agents
• Version information for Basic Input/Output System (BIOS), firmware, and operating system
• A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical components.
2
Server Administrator Storage Management MIB
dcstorag.mib
The Server Administrator Storage Management MIB provides storage management data that allows you to monitor the health of storage resources with SNMP management applications.

If interested to know about Monitoring Dell Servers using HP Operations Manager for Windows, please refer to the Dell SPI white paper here

Friday, November 20, 2015

Commands for basic FOS troubleshooting ( Brocade)


Disclaimer: The information in this Contribution is provided “AS IS,” without warranty of any kind.
The author reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use.

The author shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this contribution.


There are lots of brocade commands that come handy when troubleshooting a fabric related problems. We divide these into

Marginal Links

switchshow - Indicators like no light or In_sync will be displayed
portshow - Provides report on errors on a port
porterrshow - provides gist of port errors, look for delta of counters
portstatsshow - Provides details of port errors
portstats64show - Extension of portstatsshow when 32 bit counters do not suffice, look for tim_txcrd_z to observe BB_credit deltas

fabriclog -s - Helps isolate flapping ports, look out for offline and online sequences
sfpshow - Provides information on SFP and their state, check for power

Zoning

cfgshow - Displays zoning configuration
defzone --show  - Shows default zone settings
nsshow -t - Display name server entries with additional details

nodefind - To find specific device in fabric
nodefind - To find specific device in fabric

fcping - helps isolate end to end device connectivity and also an easy method to validate zoning


Licensing

licenseshow

Firmware Download

firmwaredownloadstatus
firmwareshow
version

Configuration

configdefault - To reset switch configuration to default
configdownload - To download a previously uploaded config file

switchshow - Lists connection information as well first indicator of fabric segmentations
errshow -r - Look for config events, match events with list in Brocade Message reference guide for suitable actions
fabstatsshow - flags any parameter mismatch during merging
fabricshow - Helps identify domain id conflicts and gives an overview of all fabric members

configure - To set correct switch and flow control parameters

portcfgshow - Display port configuration
portcfgspeed - Set or show port speed
portcfgdefaults - Set port settings to default
portcfgpersistentenable - To enable port permanently
portcfgpersistentdisable - To disable port persistently (across reboots)
portdisable
portenable
portcfgeport - Disable E port
portcfglport - Lock port to L port
portcfggport - Lock port to E or F port

Log collection

supportshow
supportsave