Wednesday, July 18, 2012

Windows 7 USB/DVD download tool

Link to original document page:
http://www.microsoftstore.com/store/msstore/html/pbPage.Help_Win7_usbdvd_dwnTool


OVERVIEW

When you choose to download most software from the Microsoft Store, you have the option of using Download Manager or downloading from your browser. However, when you purchase Microsoft Windows 7 from Microsoft Store, you have an additional choice to make: whether to download a collection of compressed files or to download an ISO file. An ISO file combines all the Windows 7 installation files into a single uncompressed file.
If you choose to download an ISO file (so that you can create a bootable file from a DVD or USB flash drive), copy your Windows 7 ISO file onto your media and, run the Windows 7 USB/DVD Download Tool. After you do this, you can install Windows 7 onto your computer directly from the USB flash drive or DVD.
NOTE: When you download the ISO file, you must copy the file onto a USB flash drive or a DVD to install Windows 7. When you're ready to install Windows 7, insert the USB flash drive into your USB port or insert your DVD into your DVD drive, and then run Setup.exe from the root folder on the drive.
The advantage to following this process and creating bootable media is that it allows you to install Windows 7 without having to first run an existing operating system on your machine. If you change the boot order of drives in your computer's BIOS, you can run the Windows 7 installation directly from your USB flash drive or from a DVD when you first turn your computer on. (Please see the documentation for your computer for information about how to change the BIOS boot order of drives.)

Download tool HERE

Monday, July 16, 2012

VSphere Web Client Demo

The demo will show how easy the new vSphere web client is to access as well as highlight the simplicity of navigating the new interface for common day-to-day tasks of virtualization administrators. For more information: www.vmware.com



Tuesday, June 26, 2012

Create a bootable Windows PE 3.0 USB drive with rescue tools – Part 1

For Windows PE 1.0, the minimalist Windows based on Windows 2003/XP, you needed an SA (Software Assurance), OEM, or ISV license. When Windows Vista was released everyone had access to Windows PE 2.0. This also applies to the Windows 7-based edition, Windows PE 3.0. Windows PE (Preinstallation Environment) was originally designed to deploy Windows. However, it is also useful in creating your own customized rescue boot media. In this article, I will describe how you can create a bootable Windows PE 3.0 (WinPE) USB stick, and, in my next post, I will show how to add your own rescue tools and how to keep your rescue stick up-to-date without much hassle. You will see that the procedure described here is much more convenient than most solutions you’ll find on the web.

Link to this greate article is:
http://4sysops.com/archives/build-a-bootable-windows-pe-3-0-usb-drive-with-rescue-tools-part-1/

Tuesday, June 19, 2012

Linux Screen Tutorial and How To

You are logged into your remote server via SSH and happily plucking along at your keyboard and then it happens. Suddenly, the characters stop moving and then you get the dreaded “Connection Closed” message. You have just lost your session. You were halfway through some task and now you have to start over. Ugh. Well you can prevent this from happening by using screen. The Linux screen tool can not only save you from disconnection disasters, but it also can increase your productivity by using multiple windows within one SSH session.

Original text of this great tutorial can be found on location:

http://www.rackaid.com/resources/linux-screen-tutorial-and-how-to/

Friday, June 1, 2012

HowTo monitor the NIC used by a Virtual Machine in a Hyper-V cluster

Original post can be found at location:
http://blogs.msdn.com/b/robertvi/archive/2008/12/05/howto-monitor-the-nic-used-by-a-virtual-machine-in-a-hyper-v-cluster.aspx

Recently I had a customer with the following problem: Hyper-V Host Clusters don't support NIC Teaming. So I have my VM clustered, but my machine does not failover when the NIC used for that machine has a problem. E.g. Network cable unplugged.
One approach to workaround this, is to add a cluster resource script to the Cluster Group. Below is a script, with short instructions.
Please note, this is a sample script, so you should consider testing and modifications to adjust for your own needs.
Unfortunately, this approach is not applicable if you manage your cluster with SCVMM 2008, as it will mark your VM as "unsupported"
This "unsupporte cluster configuration" notice in SCVMM will go away with SCVMM 2008 R2, and a April updated to SCVMM 2008

copy and paste the below and save as NicHa.vbs
'*******************************************************************************************************************************************************
' Nic HA Script. Sample. Please feedback to robertvi at microsoft.com
'
'INSTALL INSTRUCTIONS
'
' 1. copy this script to all cluster nodes into %windir%\cluster
' 2. In Failover Cluster Management Select the VM you wish to add NIC Monitoring
' 3. Select "Add a resource" -> Generic Script
' 4. Enter %windir%\cluster\nicha.vbs
' 5. Next, Finish. Note the name of the created resource (nicha Script)
' 6. Run ncpa.cpl
' 7. Identfiy the Phyiscl NIC that is used by the Switch for this VM (This NIC should only have the Switch Protocol bound)
'    Usually something like "Local Area Connection"
' 8. Rename this NIC to something like "VM Network 1"
' 9. Do steps 6 to 8 on all cluster nodes
' 10. Open a Elevated CMD Prompt
' 11. Using the names from above, "nicha script", "VM Network 1"'
' 12. In cmd prompt, issue the following command: cluster res "nicha Script" /priv NicName="VM Network 1"
' 13. Online the Script Resource
'
'You may edit the properties of the Virtual Machine Group in Failover Cluster Management to allow more failovers in a given period.
'The Default of 2 may be reached easily during testing. The script resource will then fail, but the group will not move
'
'The availability of the NIC is checked every minute by default.
'This could be changed in the Advanced Properties of the Script Resource in the "Thorough resource health check interval", if needed
'
'
'
'*******************************************************************************************************************************************************

'*******************************************************************************************************************************************************

'*******************************************************************************************************************************************************
'Global variables
'*******************************************************************************************************************************************************
'Script Version
ScriptVersion = "0.2"

'*******************************************************************************************************************************************************
'Open()
'
'*******************************************************************************************************************************************************
Function Open()
   
 On Error Resume Next
 Resource.LogInformation("Entering Open() for NIC Monitoring Generic Script Version " & ScriptVersion)
 If Resource.PropertyExists("NicName") = FALSE Then
  Resource.AddProperty("NicName")
  Resource.LogInformation("NICHA: Property NicName not configured")
 End If

Open = 0
End Function

'*******************************************************************************************************************************************************
'Online()
'

'*******************************************************************************************************************************************************
Function Online()
 'Check if the NIC is connected, otherwise fail Open
 Online = 1
 strComputer = "."
 strNicName = Resource.NicName
 strquery = "Select * from Win32_NetworkAdapter where NetConnectionID = '" & strNicName & "'"

 Set objWMIService = GetObject("winmgmts:" _
  & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
 Set colItems = objWMIService.ExecQuery(strquery)
 if colItems.Count = 0 then
  Resource.LogInformation("NICHA: Error - NIC not found")
  set objWMIService = nothing
  Set colItems = nothing
  Exit Function
 end if
 set objItem = colItems.ItemIndex(0)

 if objItem.NetConnectionStatus = 2 then
  Online = 0
 else
   Resource.LogInformation("NICHA: Error - NIC not in connected state")
 end if

 set objWMIService = nothing
 Set colItems = nothing
 set objItem = nothing

End Function

'*******************************************************************************************************************************************************
'LooksAlive()
'
'Return success
'*******************************************************************************************************************************************************
Function LooksAlive()
 On Error Resume Next
 LooksAlive = TRUE
End Function

'*******************************************************************************************************************************************************
'IsAlive()
'
'*******************************************************************************************************************************************************
Function IsAlive()
   
 On Error Resume Next
 IsAlive = FALSE
 strComputer = "."
 strNicName = Resource.NicName
 strquery = "Select * from Win32_NetworkAdapter where NetConnectionID = '" & strNicName & "'"

 Set objWMIService = GetObject("winmgmts:" _
  & "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
 Set colItems = objWMIService.ExecQuery(strquery)
 if colItems.Count = 0 then
  Resource.LogInformation("NICHA: Error - NIC not found")
  set objWMIService = nothing
  Set colItems = nothing
  Exit Function
 end if
 set objItem = colItems.ItemIndex(0)

 if objItem.NetConnectionStatus = 2 then
  IsAlive = TRUE
 else
   Resource.LogInformation("NICHA: Error - NIC not in connected state")
 end if

 set objWMIService = nothing
 Set colItems = nothing
 set objItem = nothing

End Function

'*******************************************************************************************************************************************************
'Offline()
'
'*******************************************************************************************************************************************************
Function Offline()
 On Error Resume Next
 Offline = 0
End Function

'*******************************************************************************************************************************************************
'Terminate()
'
'*******************************************************************************************************************************************************
Function Terminate()
 On Error Resume Next
 Terminate = 0

End Function
'*******************************************************************************************************************************************************
'Close()
'
'Return success
'*******************************************************************************************************************************************************
Function Close()
 Close = 0
End Function

Wednesday, May 23, 2012

Upgrade to CentOS 6.2 from CentOS 6.1 or CentOS 6.0

1. Change to root User

su -
## OR ##
sudo -i

2. Backup all important data

  • Backup /etc diretory
  • Backup important logs /var/log
  • Backup web server configs and sites
  • Dump MySQL databases
  • Dump PostgreSQL databases
  • Backup all what you need if something goes wrong

3. Check list of packages that are going to be updated

yum list updates

4. Upgrade with yum update

Official way to do upgrade:
yum update
Another way to do update is first clean all, second update glibc, yum, rpm and python packages and then update other packages like following:
yum clean all
yum update glibc* yum* rpm* python*
yum update

5. Reboot

reboot

6. Check CentOS 6.2 (Final) release info and Check your entire system

cat /etc/redhat-release
## Output ##
CentOS release 6.2 (Final)
Following needs redhat-lsb package
lsb_release -a
## Output ##
LSB Version:    :core-4.0-amd64:core-4.0-ia32:core-4.0-noarch:graphics-4.0-amd64:graphics-4.0-ia32:graphics-4.0-noarch:printing-4.0-amd64:printing-4.0-ia32:printing-4.0-noarch
Distributor ID: CentOS
Description:    CentOS release 6.2 (Final)
Release:        6.2
Codename:       Final
Check that your system is working normally and test every services.

Tuesday, May 15, 2012

SLES / SLED 11 - Multimedia VLC How-To


 To be able to use VLC player in SLES / SLED 11, it is needed to switch to openSuSE repos, in this case to  version 11.1. Do following:

zypper ar -f http://packman.unixheads.com/suse/11.1/ Packman && zypper refresh Packman

zypper ar -f http://download.videolan.org/pub/vlc/SuSE/11.1 vlc && zypper refresh vlc && zypper in vlc

If it still won't install try adding these two repos and try installing vlc again:

zypper ar -f http://download.opensuse.org/repositories/multimedia:/libs/SLE_11/ multimedia-libs && zypper refresh multimedia-libs

zypper ar -f http://download.opensuse.org/repositories/multimedia:/xine/SLE_11 multimedia-xine && zypper refresh multimedia-xine

That's is all folks :)

How to use DiskSpd to simulate Veeam Backup & Replication disk actions

This HOW-TO contains information on how to use Microsoft© DiskSpd to simulate Veeam Backup & Replication disk actions to measure disk pe...